Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 41
Filter
1.
Braz. dent. sci ; 26(3): 1-9, 2023. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1442905

ABSTRACT

Objetivo: Este estudo avaliou as propriedades de polimento dos materiais de splint oclusal obtidos usando métodos de fabricação subtrativos e aditivos com os procedimentos de polimento laboratorial (LP) e polimento em consultório (CP). Material e Métodos: As amostras (N=180, n=60 para cada grupo) foram fabricadas usando um dos seguintes métodos: método de fabricação subtrativo (SMM) (M-PM Disc, Merz Dental GmbH), método de fabricação aditivo (AMM) (Freeprint Splint 2.0, DETAX GmbH & Co. KG) e o método de fabricação convencional (CMM) (Promolux HC, Merz Dental GmbH). Seguindo os procedimentos de LP e CP, a rugosidade da superfície dos espécimes foi medida usando um perfilômetro de superfície digital. Um espécime representativo foi selecionado de cada grupo, e uma imagem de microscópio eletrônico de varredura (SEM) foi obtida. Resultados: Tanto o método de fabricação quanto os procedimentos de polimento afetaram significativamente os resultados (P<0,01). Os termos de interação também foram significativos (P<0,001). Conclusão: Com ambos os métodos de polimento, a rugosidade superficial do grupo AMM foi a maior e a do grupo CMM a menor. Embora o procedimento CP tenha sido mais eficaz do que LP com ambos os métodos, a rugosidade da superfície ficou abaixo do limite de 0,2 µm após ambos os procedimentos de polimento testados (AU)


Objective: This study evaluated the polishing properties of the occlusal splint materials obtained using subtractive and additive manufacturing methods with the laboratory-type polishing (LP) and chairside-type polishing (CP) procedures. Material and Methods: Specimens (N=180, n=60 each group) were manufactured using one of the following methods: subtractive manufacturing method (SMM) (M-PM Disc, Merz Dental GmbH), additive manufacturing method (AMM) (Freeprint Splint 2.0, DETAX GmbH & Co. KG), and the conventional manufacturing method (CMM) (Promolux HC, Merz Dental GmbH). Following LP and CP procedures, surface roughness of the specimens was measured using a digital surface profilometer. One representative specimen was selected from each group, and a scanning electron microscope (SEM) image was made. Results: Both the manufacturing method and the polishing procedures significantly affected the results (P<0.01). Interaction terms were also significant (P<0.001). Conclusion: With both polishing methods, surface roughness of the AMM group was the highest and the CMM group the least. Although the CP procedure was more effective than LP with both methods, surface roughness was below the 0.2 µm threshold after both polishing procedures tested. (AU)


Subject(s)
Surface Properties , Occlusal Splints , Computer-Aided Design , Polymethyl Methacrylate , Dental Materials
2.
J. appl. oral sci ; 31: e20230118, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1514412

ABSTRACT

Abstract Objective This study aimed to analyze the effect of irradiation on the push-out bond strength of mineral trioxide aggregate (MTA) and Biodentine to radicular dentin. Methodology A total of 60 extracted mature human teeth with single root canals were categorized into two groups (irradiated and non-irradiated) (n=30). Each group was further divided into two sub-groups based on cements used (Biodentine and MTA). Then, a cumulative radiation dose of 60 Gy was divided into 30 fractions (two Gy for every fraction) and administered for five successive days per week over six weeks. Obturation was then performed using MTA and Biodentine. Afterwards, 1.5 mm thick horizontal sections were procured from the middle one-third of all the specimens and then subjected to push-out bond test. Results were analyzed using one-way analysis of variance with post-hoc Tukey's test. Results The bond strength of Biodentine and MTA to irradiated teeth was lower than non-irradiated teeth. Highest push-out bond strength was observed in non-irradiated specimens filled with Biodentine (p=0), followed by irradiated specimens filled with Biodentine (p=0); non-irradiated specimens filled with MTA (p=0); and irradiated specimens filled with MTA (p=0.9). Conclusion The push-out bond strength of Biodentine and MTA to root canal dentin decreased significantly post irradiation.

3.
Braz. dent. sci ; 25(4): 1-14, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1395942

ABSTRACT

The current review aimed to compare the mechanical properties and clinical behavior of fiberglass and cast metal posts. It included in-vitro studies, finite element analysis, clinical studies, and systematic reviews that evaluated fiberglass and metal posts with reliable methodologies. The reports in the literature diverge on tooth failure modes and stress distributions in the root according to different posts. Investigations suggest that fiberglass posts are preferable because their elastic modulus is similar to dentin. Other studies mention that the flexibility of fiber posts may damage the interface. The fracture load values of different studies could not be compared. The presence of a ferrule seems beneficial. Cast metal posts provide higher characteristic strength to the set but with more unfavorable failures. Intraradicular posts with a lower elastic modulus produce more stress between the cement layer and dentin. In conclusion, fiberglass and cast metal posts can be used with a ferrule. Cast metal posts seem more appropriate for weakened teeth. The presence of a ferrule benefits the system. Weakened teeth tolerate higher loads when restored with cast metal posts, but when these posts fail, the only solution is tooth extraction. Clinical follow-ups cannot yet detect differences between the survival rates of intraradicular fiberglass and cast metal posts (AU)


O objetivo da presente revisão foi comparar as propriedades mecânicas e o comportamento clínico de pinos de fibra de vidro e núcleos metálicos fundidos. Estudos laboratoriais, analise por elementos finitos, estudos clínicos e revisões sistemáticas que avaliaram pinos de fibra de vidro e metálicos, com metodologia confiável foram selecionados. A literatura mostra-se bastante controversa sobre os modos de falha do dente e a distribuição de tensões na raiz de acordo com diferentes tipos de pinos. Algumas investigações sugerem que pinos de fibra de vidro são preferíveis porque seu módulo de elasticidade é semelhante ao da dentina, enquanto outras mencionam que a flexibilidade do pino de fibra pode ser prejudicial à interface adesiva. Os valores de carga de fratura em diferentes estudos não podem ser comparados. A presença de férula é benéfica. O núcleo metálico fundido resulta em maior resistência característica do conjunto, mas falhas mais desfavoráveis. Também, pinos com menor módulo geram mais tensão entre a camada de cimento e a dentina. Em conclusão, verificou-se que tanto pino de fibra de vidro como núcleo metálico fundido podem ser utilizados quando a férula está presente. Os núcleos metálicos fundidos parecem ser mais indicados para dentes fragilizados. É evidente que a presença de férula é benéfica para o sistema. Dentes fragilizados toleram cargas maiores quando restaurados com núcleos metálicos fundidos; porém, quando falham, a única solução é a extração do dente. Os acompanhamentos clínicos ainda não são capazes de detectar diferença entre as taxas de sobrevivência dos pinos de fibra de vidro e núcleos metálicos (AU)


Subject(s)
Prosthodontics , Dental Prosthesis , Finite Element Analysis , Dental Pins
4.
Braz. dent. sci ; 25(4): 1-7, 2022. tab
Article in English | LILACS, BBO | ID: biblio-1397461

ABSTRACT

Objective: The rough surfaces of removable appliances used in pediatric dentistry or orthodontics, may result in an environment for biofilm accumulation, yielding to enamel demineralization. This study aimed to assess the effects of adding nanoparticles of bioactive glass to polymethylmethacrylate to promote the antibacterial activity in acrylic resins. Material and Methods: Acrylic resin specimens (20x20x1mm3) were prepared by adding 2% or 5% bioactive glass. The specimens in the control group without bioactive glass were prepared from the mixture of acrylic powder containing nanoparticles and liquid monomer (n=10 per group). The antibacterial activity of the specimens against Streptococcus mutans and Lactobacillus acidophilus activity in biofilm was investigated through counting colony forming units (CFU). Data were analyzed using a one-way analysis of variance and Tukey's post hoc tests at the significance level of 0.05. Results: The incorporation of 2% (p=0.001) and 5% (p<0.001) bioactive glass in acrylic resin reduced the metabolic activity and CFU of L. acidophilus. For S.mutans, antimicrobial activity was observed only with the 5% concentration of bioactive glass, and this group was statistically different from the control (p<0.001). When L. acidophilus was exposed to polymethyl methacrylate with 5% bioactive glass, significant decrease was observed compared to the control group (p<0.05). Conclusion: Adding bioactive glass nanoparticles into the acrylic resins used for fabricating removable appliances revealed a greater antibacterial effect against cariogenic bacteria tested (AU)


Objetivo: As superfícies rugosas dos aparelhos removíveis utilizados em Odontopediatria ou Ortodontia, podem resultar em um ambiente para acúmulo de biofilme, cedendo à desmineralização do esmalte. Este estudo teve como objetivo avaliar os efeitos da adição de nanopartículas de vidro bioativo ao polimetilmetacrilato para promover a atividade antibacteriana em resinas acrílicas. Material e Métodos: Amostras de resina acrílica (20x20x1 mm3) foram preparadas pela adição de 2% ou 5% de vidro bioativo. Os corpos de prova do grupo controle sem vidro bioativo foram preparados a partir da mistura de pó acrílico contendo nanopartículas e monômero líquido (n=10 por grupo). A atividade antibacteriana dos espécimes sobre a atividade de Streptococcus mutans e Lactobacillus acidophilus em biofilme foi investigada através da contagem de unidades formadoras de colônias (UFC). Os dados foram analisados por meio de análise de variância unidirecional e testes post hoc de Tukey com nível de significância de 0,05. Resultados: A incorporação de 2% (p=0,001) e 5% (p<0,001) de vidro bioativo em resina acrílica reduziu a atividade metabólica e UFC de L. acidophilus. Para S. mutans, a atividade antimicrobiana foi observada apenas com a concentração de 5% de vidro bioativo, sendo este grupo estatisticamente diferente do controle (p<0,001). Quando L. acidophilus foi exposto ao polimetilmetacrilato com 5% de vidro bioativo, foi observada diminuição significativa em relação ao grupo controle (p<0,05). Conclusão: A adição de nanopartículas de vidro bioativo nas resinas acrílicas utilizadas na fabricação de aparelhos removíveis revelou um maior efeito antibacteriano contra as bactérias cariogênicas testadas(AU)


Subject(s)
Acrylic Resins , Dental Materials , Dentists , Anti-Bacterial Agents
5.
Braz. oral res. (Online) ; 36: e042, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1364601

ABSTRACT

Abstract: Although the effects of different intraoral scanners, model scanners, and CAM units on the marginal and internal fitting of restorations have been investigated, the effects of CAD software in particular has not been evaluated. The marginal and internal fit of indirect restorations may vary according to the CAD software used, even when using the same intraoral scanner and milling machine. The purpose of this study was to evaluate the marginal and internal fit of milled full ceramic crowns designed with three different CAD systems. Eleven typodont maxillary first premolar teeth were prepared and scanned using a 3Shape TRIOS Intraoral Dental Scanner. The obtained STL scan data were exported and used to design a full crown using three different CAD systems (CEREC, KaVo, and Planmeca). An independent milling unit was used to manufacture the crowns for each group (n = 11). The marginal and internal fit were evaluated for each restoration using 2D and 3D micro-CT analysis. For 2D analysis, 18 measurements for each sample were made, covering the marginal (Marginal Gap Buccal (MG-A), Marginal Gap Palatinal (MG-B), Finish Line Buccal (FL-A), Finish Line Palatinal (FA-B)) and internal fit locations (Axial Wall Buccal (AW-A), Axial Wall Palatinal (AW-B), Lingual Cusp (LC), Buccal Cusp (BC), and Occlusal Central Fossa (OCF)). Statistical analyses were performed using Open Source R Statistical Software (α = 0.05) The results of Duncan's multiple range test showed that the values for the marginal measurement points MG-A, MG-B, FL-A, and FL-B in the Planmeca group were significantly higher than the values obtained in the CEREC and KaVo groups (p < 0.05). In AW1, values of the CEREC group were found to be higher than those of the KaVo and Planmeca groups (p < 0.05). CAD software showed an effect on the marginal fit values of crowns whereas no significant difference was observed in terms of the internal fit, except for a single measurement point made from the buccal direction.

6.
Braz. j. oral sci ; 20: e213981, jan.-dez. 2021. ilus
Article in English | BBO, LILACS | ID: biblio-1254747

ABSTRACT

Aim: To compare the microleakage of Cention N, a subgroup of composite resins with a resin-modified glass ionomer (RMGI) and a composite resin. Methods: Class V cavities were prepared on the buccal and lingual surfaces of 46 extracted human molars. The teeth were randomly assigned to four groups. Group A: Tetric N-Bond etch-and-rinse adhesive and Tetric N-Ceram nanohybrid composite resin, group B: Cention N without adhesive, group C: Cention N with adhesive, and group D: Fuji II LC RMGI. The teeth were thermocycled between 5°-55°C (×10,000). The teeth were coated with two layers of nail vanish except for 1 mm around the restoration margins, and immersed in 2% methylene blue (37°C, 24 h) before buccolingual sectioning to evaluate dye penetration under a stereomicroscope (×20). The data were analyzed by the Kruskal-Wallis and Wilcoxon tests (α=0.05). Results: Type of material and restoration margin had significant effects on the microleakage (p<0.05). Dentin margins showed a higher leakage score in all groups. Cention N and RMGI groups showed significant differences at the enamel margin (p=0.025, p=0.011), and for the latter group the scores were higher. No significant difference was found at the dentin margins between the materials except between Cention N with adhesive and RMGI (p=0.031). Conclusion: Microleakage was evident in all three restorative materials. Cention N groups showed similar microleakage scores to the composite resin and displayed lower microleakage scores compared with RMGI


Subject(s)
Composite Resins , Dental Leakage , Glass Ionomer Cements , Molar, Third
7.
Braz. dent. j ; 32(3): 44-55, May-June 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1345505

ABSTRACT

Abstract In the RLT (Rapid Layer Technology), veneering ceramic and framework are fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM) and then cemented to obtain the restoration. This study aimed to evaluate the effect of the thickness of veneering ceramic manufactured by the RLT technique on the fracture resistance (FR) of bilayer crowns with zirconia frameworks. Twenty zirconia frameworks and twenty feldspathic posterior crowns with two different veneering ceramic occlusal thicknesses (1mm=TF1; 2mm=TF2) were manufactured using CAD/CAM system. The specimens were luted to an epoxy resin abutment with resin cement and mechanically cycled (200N and 4.5×105 Pa, 37°C, 2×106 cycles, 3Hz). The FR test was performed (10kN, 0.5mm/min), and the specimens were analyzed in a stereomicroscope. For the stress analysis (finite element analysis, FEA), a 10kN load was equal to the in vitro test, and the principal stress was evaluated. The FR data were analyzed by Student's t-test and Weibull's analysis. The thickness influenced the FR of bilayer crowns. The FR was higher in the TF2 than in the TF1 group. The TF2 group presented the highest characteristic strength compared to the group TF1. The predominant type of failure was delamination. The FEA showed higher stress concentrations below the loading application point at the veneering cement interface in the 1-mm-thick model. The bilayer crowns manufactured using the approach of 2mm of veneering ceramic promoted higher FR compared to the group with 1mm veneering ceramic. Also, the FEA showed that the veneer ceramic thickness has an effect on stress distribution in zirconia-based bilayer crowns.


Resumo Na RLT (Rapid Layer Technology), a cerâmica de cobertura e infraestrutura são fabricados pelo Computer-Aided Design / Computer-Aided Manufacturing (CAD / CAM) e cimentados para obter a restauração. Este estudo teve como objetivo avaliar o efeito da espessura da cerâmica de cobertura fabricada pela técnica RLT na resistência à fratura (RF) de coroas bilaminadas com infraestrutura de zircônia. Vinte infraestruturas de zircônia e vinte coroas posteriores feldspáticas com duas espessuras oclusais da cerâmica de cobertura (1mm = TF1; 2mm = TF2) foram fabricadas usando o sistema CAD / CAM. Os espécimes foram cimentados em preparos de resina epóxi com cimento resinoso dual e ciclados mecanicamente (200N e 4,5×105 Pa, 37° C, 2×106 ciclos, 3Hz). O teste de RF foi realizado (10kN, 0,5mm / min) e, posteriormente, os espécimes foram analisados em estereomicroscópio. Para a análise de tensão (análise de elementos finitos, FEA), uma carga de 10kN foi aplicada igual ao teste in vitro, e a tensão principal foi avaliada. Os dados de RF foram analisados pelo teste t de Student e análise de Weibull. A espessura mostrou forte influência na RF das coroas bilaminadas. A RF foi maior em TF2 do que no grupo TF1. O grupo TF2 apresentou a maior resistência característica em relação ao grupo TF1. O tipo de falha predominante foi a delaminação. O FEA mostrou maiores concentrações de tensões abaixo do ponto de aplicação da carga, na interface cimento e cerâmica de cobertura no modelo de coroa de 1 mm de espessura. As coroas de bilaminadas confeccionadas com 2 mm de cerâmica de cobertura promoveram maior RF em comparação ao grupo com cerâmica de cobertura de 1 mm. Além disso, a FEA mostrou que a espessura da cerâmica de cobertura tem um efeito na distribuição de tensões em coroas bilaminadas à base de zircônia.


Subject(s)
Humans , Dental Porcelain , Dental Veneers , Technology , Zirconium , Materials Testing , Ceramics , Computer-Aided Design , Dental Restoration Failure , Crowns , Dental Stress Analysis
8.
Braz. dent. sci ; 24(4, suppl 1): 1-7, 2021. ilus
Article in English | LILACS, BBO | ID: biblio-1352608

ABSTRACT

Background: Burning mouth syndrome (BMS) is a non-neuropathic chronic orofacial pain condition, characterized by the presence of burning/warm sensation without specific mucosal lesions. Objective: The aim of the present clinical case report is to describe the positive outcome of dental treatment of a patient with BMS and followed up for 25 years. Data Treatment: This report describes the case of a 50-year-old black woman sought treatment for burning, and persistent swelling of tong (24h/day) occurring over years. Clinical evaluation of the oral environment revealed the tongue with cracking, darkened points areas, surrounded by whitish areas. Twelve teeth presented extensive amalgam restorations. Patch testing revealed a very strong hypersensitivity to Amalgam. All amalgam restorations were substituted by composite resin restorations. Results and Conclusion: Burning sensation disappeared completely after these restorations had been changed. After 25-year follow-up period, it was observed that burning sensation has never been felt anymore. Clinical Significance: Burning mouth syndrome is a chronic orofacial pain, usually without specific mucosal lesions. The etiology is complex and multifactorial and the treatment should be made specifically for each pacient. (AU)


Introdução: A síndrome de ardência bucal (SAB) é uma condição de dor orofacial crônica não neuropática, caracterizada pela presença de sensação de queimação/calor sem lesões específicas da mucosa. Objetivo: Oobjetivo do presente relato de caso clínico é descrever a evolução positiva do tratamento odontológico de uma paciente com SAB e o retorno após 25 anos. Tratamento dos Dados: Este relato descreve o caso de uma mulher negra de 50 anos que buscou tratamento por queimadura e edema persistente da língua (24h/dia) ocorrendo ao longo dos anos. A avaliação clínica da cavidade bucal revelou a língua com áreas fissuradas e áreas com pontos escurecidos circundadas por áreas esbranquiçadas. Doze dentes apresentavam restaurações extensas de amálgama de prata. O teste de contato revelou hipersensibilidade muito forte ao amálgama de prata. Todas as restaurações de amálgama de prata foram substituidas por restaurações de resina composta. Resultados e Conclusão: A sensação de queimação desapareceu completamente após a substituição das restaurações. Após um periodo de 25 anos, observou-se que a sensação de queimação nunca foi mais relatada. Significado Clínico: a síndrome da ardência bucal é uma dor orofacial crônica, geralmente sem lesões específicas da mucosa. A etiologia é complexa e multifatorial e o tratamento deve ser feito especificamente para cada paciente.(AU)


Subject(s)
Humans , Female , Adult , Burning Mouth Syndrome , Composite Resins , Dental Amalgam
9.
Braz. dent. sci ; 24(1): 1-9, 2021. tab
Article in English | BBO, LILACS | ID: biblio-1145369

ABSTRACT

Objective: The aim of the study was to assessment of technical quality of 9562 endodontic cases treated by heterogeneous groups with different clinical experience. Material and methods: This retrospective study reviewed the dental records of 8590 patients (9562 endodontic cases and 13203 root canals including 3340 retreatment root canals) treated by fourth-year undergraduates, fifth-year undergraduates, endodontic program students, and endodontic specialists between December 2017 and December 2018 at the Department of Endodontics of Necmettin Erbakan University Faculty of Dentistry in Konya. The length, density, and taper of root fillings, the acceptable technical quality of the root filling criteria, and the presence of procedural errors, were recorded. Chi-square tests with a significance level at p=0.05 were used for statistical analysis. Results: Acceptable root fillings were found in 71.5% of endodontic cases. Clinical experience showed statistical differences in the root filling quality among fourth-year undergraduates, fifth-year undergraduates, endodontic program students, and specialists (52, 63.1, 77.9 and 86.5% respectively). Fractured instruments and missed canals were noted in 9.8% and 0.57% of cases treated by endodontic program students significantly more than the other clinical experiences. No statistical differences were found among the clinical experiences in other procedural errors. No statistically significant differences were found between age range and gender in additional root canals. Statistically significant differences were observed between the number of root canal retreatments in terms of age range and gender. Conclusions: Clinical experience affects the technical quality of root canal treatments. Fractured instruments and missed canals, especially by endodontic program students, should be given more attention. (AU)


Objetivo: O objetivo do estudo foi avaliar a qualidade técnica de 9562 casos endodônticos tratados por grupos heterogêneos com diferentes experiências clínicas. Material e métodos:Este estudo retrospectivo revisou os registros dentários de 8590 pacientes (9562 casos endodônticos e 13203 canais radiculares, incluindo 3340 canais radiculares de retratamento) tratados por graduandos do quarto ano, graduandos do quinto ano, estudantes do programa endodôntico e especialistas em endodontia, entre dezembro de 2017 e dezembro de 2018 no Departamento de Endodontia da Faculdade de Odontologia da Universidade Necmettin Erbakan em Konya. O comprimento, a densidade e a conicidade dos preenchimentos das raízes, a qualidade técnica aceitável dos critérios de preenchimento das raízes e a presença de erros processuais foram registrados. Os testes de qui-quadrado com nível de significância de p = 0,05 foram utilizados para análise estatística. Resultados:O preenchimento radicular aceitável foi encontrado em 71,5% dos casos endodônticos. A experiência clínica mostrou diferenças estatísticas na qualidade do preenchimento das raízes entre os alunos do quarto ano, do quinto ano, estudantes do programa endodôntico e especialistas (52, 63,1, 77,9 e 86,5%, respectivamente). Instrumentos fraturados e canais perdidos foram observados em 9,8% e 0,57% dos casos tratados pelos estudantes do programa endodôntico significativamente mais do que nas outras experiências clínicas. Não foram encontradas diferenças estatísticas entre as experiências clínicas em outros erros processuais. Não foram encontradas diferenças estatisticamente significantes entre faixa etária e sexo em canais radiculares adicionais. Foram observadas diferenças estatisticamente significantes entre o número de retratamentos do canal radicular em termos de faixa etária e sexo. Conclusões: A experiência clínica afeta a qualidade técnica dos tratamentos do canal radicular. Instrumentos fraturados e canais perdidos, especialmente por estudantes do programa endodôntico, devem receber mais atenção (AU)


Subject(s)
Humans , Students, Dental , Radiography, Dental , Dental Pulp Cavity , Education
10.
Braz. dent. sci ; 24(4): 1-13, 2021. tab, ilus, graf
Article in English | LILACS, BBO | ID: biblio-1293066

ABSTRACT

Objective: Dentists need a high level of awareness to limit the spread of COVID-19 (Coronavirus disease 2019). This study aimed to evaluate the level of awareness and attitude regarding the risk associated with dental procedures among dentists. Material and Methods: An online questionnaire was submitted to dentists between April- May 2020. The questionnaire form included questions related to demographic data, the transmission characterization of SARS-CoV-2, and treatment of COVID-19 patients. Data were analyzed using IBM SPSS V23 and chi-square test (p ≤ 0.05). Results: A total of 3825 participants (29.1± 7.6 years) were included. In COVID-19, the riskiest dental branch in terms of the risk of contamination through saliva was considered to be Periodontics (32.2%), while the least risky branch was Orthodontics (0.2%). Specific dental treatment procedures considered at high risk of contamination were tooth preparation (69.4%), scaling and root planing (63.5%), filling (53.4%), and pulpectomy (40.5%). The parameters of the study that differed according to gender and professional status were the viability of the virus, the risk assessment, saliva contamination risk, and aerosol-generating activities for COVID-19 (p < 0.05). Conclusion: Dentists were aware of the risk assessment and extra precautionary methods. However, they had limited knowledge about the viability of the virus. Dentists should be aware of recommended approaches and update their knowledge about COVID-19 to limit the spread of the disease. Since dentistry is an area suitable for the transmission of the COVID-19, the fact that dentists have information about the viability of this virus will be lifesaving in clinical applications (AU)


Objetivo: Os dentistas precisam de um alto nível de conhecimento para limitar a disseminação de COVID-19 (doença por coronavírus 2019). Este estudo teve como objetivo avaliar o nível de consciência e atitude em relação ao risco associado aos procedimentos odontológicos entre os dentistas. Material e Métodos: Um questionário online foi submetido aos dentistas entre abril e maio de 2020. O formulário do questionário incluía questões relacionadas aos dados demográficos, à caracterização da transmissão da SARS-CoV-2 e ao tratamento de pacientes com COVID-19. Os dados foram analisados usando IBM SPSS V23 e teste do qui-quadrado (p ≤ 0,05). Resultados:Um total de 3825 participantes (29,1 ± 7,6 anos) foram incluídos. Na COVID-19, o ramo odontológico de maior risco em termos de risco de contaminação pela saliva foi considerado a Periodontia (32,2%), enquanto o ramo de menor risco foi a Ortodontia (0,2%). Os procedimentos odontológicos específicos considerados de alto risco de contaminação foram preparo dentário (69,4%), raspagem e alisamento radicular (63,5%), obturação (53,4%) e pulpectomia (40,5%). Os parâmetros do estudo que diferiram de acordo com sexo e status profissional foram a viabilidade do vírus, a avaliação de risco, risco de contaminação da saliva e atividades geradoras de aerossol para COVID-19 (p <0,05). Conclusão: Os dentistas estão cientes da avaliação de risco e dos métodos de precaução extra. No entanto, eles tinham conhecimento limitado sobre a viabilidade do vírus. Os dentistas devem estar cientes das abordagens recomendadas e atualizar seus conhecimentos sobre COVID-19 para limitar a propagação da doença. Como a odontologia é uma área propícia para a transmissão da COVID-19, se dentistas tiverem informações sobre a viabilidade desse vírus poderão salvar vidas em aplicações clínicas. (AU)


Subject(s)
Humans , Risk , Dentistry , Microbial Viability , SARS-CoV-2 , COVID-19
11.
Braz. dent. j ; 31(3): 272-280, May-June 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1132305

ABSTRACT

Abstract The purpose of this study was to evaluate the influence of the application mode of three universal adhesive systems on interfacial physical properties of indirect composite restorations adhesively cemented to dentin cavities. Seventy-eight bovine lower incisors were selected and a slice of dentin (thickness: 2 mm) between the buccal surface and pulp chamber was obtained for each tooth. Conical cavities were made on this surface. The internal walls of the cavities were then coated with a hydrophilic gel, filled with composite resin and photopolymerized. The dentin/cone sets were divided into 6 groups (n=10) according to type of universal adhesive (TETRI: Tetric N Bond, FUT: Futura Bond U, SBU: Single Bond Universal) and acid etching on dentin (A: with acid etching; WA: without acid etching). The acid etching and the adhesive systems were applied to the surface of the dentin. All composite resin cones were sandblasted (Al2O3, 20 s) and silanized. After surface treatment, the cones were cemented (RelyX Ultimate) into the dentin cavity and photopolymerized. After thermocycling (10,000 cycles), samples were submitted to marginal adaptation analysis (using caries detector dye), push-out test (0.5 mm/min), and failure mode analysis. Additional samples were prepared for nanoleakage analysis (SEM). The data (MPa) were analyzed by two-way ANOVA and Tukey's post-test (5%). The groups in which the dentin was acid etched showed significantly lower bond strength values in the push-out test (p<0.01). Dentin acid etching significantly reduced the bond strength between universal adhesive systems and dentin in indirect restorative procedures.


Resumo O objetivo deste estudo foi avaliar a influência do modo de aplicação de três sistemas adesivos universais nas propriedades físicas interfaciais de restaurações indiretas de compósito adesivamente cimentadas a cavidades dentinária. Setenta e oito incisivos inferiores bovinos foram selecionados e uma fatia de dentina (espessura: 2 mm) entre a face vestibular e a câmara pulpar foi obtida para cada dente. Cavidades cônicas foram feitas nesta superfície. As paredes internas das cavidades foram então revestidas com um gel hidrofílico, preenchidas com resina composta, e fotopolimerizados. Os conjuntos dentina/cone foram divididos em 6 grupos (n=10) de acordo com o tipo de adesivo universal (TETRI: Tetric N Bond, FUT: Futura Bond U, SBU: Single Bond Universal) e ácido na dentina (A: com condicionamento ácido; WA: sem condicionamento ácido). O condicionamento ácido e os sistemas adesivos foram aplicados na superfície da dentina. Todos os cones de resina composta foram jateados (Al2O3, 20 s) e silanizados. Após o tratamento superficial, os cones foram cimentados (RelyX Ultimate) na cavidade dentinária e fotopolimerizados. Após a termociclagem (10.000 ciclos), as amostras foram submetidas a análise de adaptação marginal (usando corante detector de carie), teste push-out (0,5 mm/min) e análise do modo de falha. Amostras adicionais foram preparadas para análise de nanoinfiltração (MEV). Os dados (MPa) foram analisados por ANOVA dois fatores e pós-teste de Tukey (5%). Os grupos em que a dentina foi condicionada por ácido apresentaram valores significativamente menores de resistência de união no teste push-out (p<0,01). O condicionamento ácido da dentina reduziu significativamente a resistência de união entre sistemas adesivos universais e dentina em procedimentos restauradores indiretos.


Subject(s)
Animals , Dental Bonding , Dentin-Bonding Agents , Surface Properties , Tensile Strength , Materials Testing , Cattle , Composite Resins , Resin Cements , Dental Cements , Dental Pulp Cavity , Dentin
12.
J. appl. oral sci ; 28: e20200122, 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1143143

ABSTRACT

Abstract This paper aims to evaluate the effect of different surface treatments on surface topography, wettability, and shear bond strength of resin cement to glass ceramic. Methodology: For SBS test, 32 blocks (7x7x2 mm) of lithium disilicate were obtained and randomly divided into eight groups (four blocks per group) according to each surface treatment (HF 20 s, 60 s, 120 s + silanization/S or Scotch Bond Universal/ SBU) and the Monobond Etch & Prime - MEP application followed or not by SBU. On each treated surface ceramic block, up to four dual-curing resin cement cylinders were prepared and light-cured for 40s (N=120/n=15). The specimens were thermocycled (10,000 cycles, 5-55°C, 30 s) and the SBS test (50KgF, 0.5 mm/min) was performed. Furthermore, failure analysis, wettability, AFM, and SEM were carried out. SBS data (MPa) were analyzed using Student's t-test, two-way ANOVA, Tukey's test (5%) and Weibull's analysis. Results: For HF experimental groups, two-way ANOVA presented the factors "etching time" and "bonding agent" as significant (p<0.05). After silane application, the HF groups presented similar bond strength. SBU application compromised the SBS, except for 120s etching time (HF120sS: 23.39ᵃ±6.48 MPa; HF120sSBU: 18.76ᵃ±8.81MPa). For MEP groups, SBU application did not significantly affect the results (p=0.41). The MEP group presented the highest Weibull modulus (4.08A) and they were statistically different exclusively from the HF20sSBU (0.58B). Conclusion: The HF 20s, 60s, 120 s followed by silane, promoted similar resin-bond strength to ceramic and the SBU application after HF or MEP did not increase the SBS.


Subject(s)
Ceramics , Dental Bonding , Wettability , Dental Porcelain , Silanes , Surface Properties , Materials Testing , Resin Cements , Dental Cements
13.
Braz. dent. sci ; 23(4): 1-12, 2020. tab, ilus
Article in English | BBO, LILACS | ID: biblio-1121881

ABSTRACT

Objective: The aim of this study was to evaluate and compare the microtensile bond strengths of four current adhesive materials that contain different monomers at deep and superficial dentin. Material and Methods: Forty non-carious human third molars (n=5) were used in the study. Specimens were divided into two main groups according to dentin thickness as superficial and deep dentin. Groups were further divided into four subgroups in terms of the adhesive systems used: Nova Compo B Plus (NCBP), Nova Compo B (NCB), Futurabond M (FB) and Clearfil S3 Bond Plus (CS3). All specimens were bonded to resin composite and stored in 37 °C water for 9-months. Teeth were sectioned into 3 x 3 mm thick beams. Microtensile bond strength test was carried out by using a universal testing device (1 mm/min). After fracture, failure types were observed using an optical microscope and the fractured dentin surfaces were observed by a scanning electron microscopy (SEM). One-way ANOVA and Tukey tests were used to compare the adhesive system in each dentin group. An unpaired T-test was used to compare the dentin thickness in each adhesive material. Results: As compared to deep dentin, superficial dentin showed higher µTBS values in groups NCBP, FB and CS, as opposed to group NCB. Only NCB revealed higher bond strength at deep dentin layers when compared to superficial dentin. In the superficial dentin group, NCBP showed the highest bond strength value while NCB showed the lowest bond strength. In the deep dentin group, while NCB showed the highest bond strength value, NCBP revealed the lowest bond strength value after 9-months storage. While 4-META and 10-MDP monomer combination (NCBP) resulted in the highest bond strength value among the adhesive systems in the superficial dentin group, the GPDMA and 4-META monomer combination (NCB) resulted in the highest bond strength in deep dentin group. Conclusions: Microtensile bond strength performance are affected by both the type of monomer in the adhesive combination and the depth of the dentin. (AU)


Objetivo: o objetivo deste estudo foi avaliar e comparar a resistência de união à microtração de quatro materiais adesivos atuais que contêm monômeros diferentes na dentina profunda e superficial. Material e Métodos: Quarenta terceiros molares humanos não cariados (n = 5) foram usados no estudo. Os espécimes foram divididos em dois grupos principais de acordo com a espessura da dentina em superficial e profunda. Os grupos foram subdivididos em quatro subgrupos quanto aos sistemas adesivos usados: Nova Compo B Plus (NCBP), Nova Compo B (NCB), Futurabond M (FB) e Clearfil S3 Bond Plus (CS3). Todos os espécimes foram aderidos à resina composta e armazenados em água a 37 ° C por 9 meses. Os dentes foram seccionados em palitos de 3 x 3 mm de espessura. O teste de microtração foi realizado com o uso de um dispositivo de teste universal (1 mm / min). Após a fratura, os tipos de falha foram observados em microscópio óptico e as superfícies de dentina fraturadas por microscopia eletrônica de varredura (MEV). Os testes ANOVA e Tukey um fator foram usados para comparar o sistema adesivo em cada grupo de dentina. Um teste T não pareado foi usado para comparar a espessura da dentina em cada material adesivo. Resultados: Em comparação com a dentina profunda, a dentina superficial apresentou maiores valores de µTBS nos grupos NCBP, FB e CS, ao contrário do grupo NCB. Apenas NCB revelou maior resistência de união na dentina profunda quando comparada à dentina superficial. No grupo de dentina superficial, NCBP apresentou o maior valor de resistência de união, enquanto NCB apresentou a menor resistência de união. No grupo de dentina profunda, enquanto NCB apresentou o valor de resistência de união mais alto, NCBP revelou o valor de resistência de união mais baixo após 9 meses de armazenamento. Enquanto a combinação de monômero 4-META e 10-MDP (NCBP) resultou no maior valor de resistência de união entre os sistemas adesivos no grupo de dentina superficial, a combinação de monômero (NCB) resultou na maior força de união no grupo de dentina profunda. Conclusões: O desempenho da resistência de união à microtração é afetado tanto pelo tipo de monômero na combinação adesiva quanto pela profundidade da dentina. (AU)


Subject(s)
Humans , Microscopy, Electron, Scanning , Dentin-Bonding Agents , Dentin , Molar
14.
Braz. dent. sci ; 23(4): 1-9, 2020. tab, ilus
Article in English | BBO, LILACS | ID: biblio-1121989

ABSTRACT

Objective: Vital bleaching is a popular treatment option for discolored teeth; but at post-treatment stage, loss of adhesion is highly reported. Literature focused on antioxidant application for the answer of this issue. The aim of this study was to compare the effects of six different antioxidants on color stability of bleached teeth. Material and Methods: This study included total of 84 extracted intact non-carious lower incisors. 35% hydrogen peroxide was applied on the labial surfaces of specimens in accordance with manufacturer's instructions. The bleached teeth were divided into 7 groups. No antioxidants were applied to the control group. For the experimental groups, the following antioxidants were applied for 10 minutes each: 5% proanthocyanidin, 5% sodium ascorbate, 5% lycopene, %5 green tea, %5 white tea and %5 α-tocopherol. CIE L*, a* and b* values of the teeth were measured by a spectrophotometer. One-way ANOVA was used to determine the differences among the groups. Multiple comparisons were examined with Tukey HSD. Results: The one-way ANOVA test revealed a statistically significant difference between the groups (p < 0.005). Highest color change was observed in lycopene group and the lowest in green tea group. Conclusion: Proanthocyanidin, white tea and green tea could be considered as post-bleaching antioxidant alternatives based on their herbal nature. (AU)


Objetivo: O clareamento vital é uma opção popular de tratamento para dentes descoloridos, mas na fase pós-tratamento, a perda de adesão é altamente relatada. A literatura enfocou a aplicação de antioxidantes para a resposta desta questão. O objetivo deste estudo foi comparar os efeitos de seis diferentes antioxidantes na estabilidade da cor de dentes clareados. Material e Métodos: Este estudo incluiu um total de 84 incisivos inferiores extraídos, intactos e não cariados. Peróxido de hidrogênio a 35% foi aplicado nas superfícies labiais dos espécimes de acordo com as instruções do fabricante. Os dentes clareados foram divididos em 7 grupos. Nenhum antioxidante foi aplicado ao grupo controle. Para os grupos experimentais, os seguintes antioxidantes foram aplicados por 10 minutos cada: proantocianidina a 5%, ascorbato de sódio a 5%, licopeno a 5%, chá verde a 5%, chá branco a 5% e α-tocoferol a 5%. Os valores CIE L *, a * e b * dos dentes foram medidos por um espectrofotômetro. ANOVA um fator foi usada para determinar as diferenças entre os grupos. As comparações múltiplas foram examinadas com Tukey HSD. Resultados: O teste ANOVA revelou uma diferença estatisticamente significativa entre os grupos (p <0,005). A maior mudança de cor foi observada no grupo do licopeno e a menor no grupo do chá verde. Conclusão: Proantocianidina, chá branco e chá verde podem ser considerados como alternativas antioxidantes pós-clareamento com base em sua natureza fitoterápica. (AU)


Subject(s)
Humans , Tea , alpha-Tocopherol , Proanthocyanidins , Lycopene
15.
Braz. dent. sci ; 23(3): 1-9, 2020. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1103728

ABSTRACT

Objective: Endodontically obturated teeth have lower fracture resistance depending on the obturating material and technique. The purpose of this study was therefore to evaluate the influence of ProRoot MTA (Dentsply Sirona, Tulsa Division) and OrthoMTA III (BioMTA, Daejeon, Korea) as an obturating material on the fracture resistance of endodontically treated teeth. Material and Methods: Thirty extracted human maxillary central incisors were decoronated and instrumented using Protaper instruments (size F5). Irrigation was performed with 2.5% sodium hypochlorite between each instrument change followed by 7% maleic acid for one minute. Finally, canals were flushed with 5 ml of PBS solution for one minute. Samples were then divided into three groups. Group I- positive control (no root canal filling); Group II- obturation with ProRoot MTA; Group III- obturation with OrthoMTA III. Ten teeth were randomly selected as a negative control in which no treatment was performed. All the specimens were then subjected to fracture strength testing using universal testing machine. For evaluation of biomineralization, six maxillary central incisors were divided into two groups. Group I obturated with ProRoot MTA and group II obturated with OrthoMTA III. These samples were subjected to SEM analysis. Results: Positive control group demonstrated the least fracture resistance, while OrthoMTA III group showed the highest fracture resistance. There was no significant difference between negative control group and ProRoot MTA groups (p=0.821). OrthoMTA III group showed better tubular biomineralization when compared to ProRoot MTA. Conclusions: Root canals obturated with OrthoMTA III had better fracture resistance and increased tubular biomineralization compared to ProRoot MTA. Since root canals obturated with OrthoMTA III had better fracture resistance, it can be used as a promising obturating material.(AU)


Objetivo: Dentes obturados endodonticamente apresentam menor resistência à fratura, dependendo do material e da técnica de obturação. Portanto, o objetivo deste estudo foi avaliar a influência do ProRoot MTA (Dentsply Sirona, Tulsa Division) e OrthoMTA III (BioMTA, Daejeon, Coréia) como material obturador na resistência à fratura de dentes tratados endodonticamente. Material e Métodos: Trinta incisivos centrais superiores humanos extraídos foram decoronados e instrumentados com instrumentos Protaper (tamanho F5). A irrigação foi realizada com hipoclorito de sódio a 2,5% entre cada troca de instrumento, seguida por ácido maleico a 7% por um minuto. Finalmente, os canais foram lavados com 5 ml de solução de PBS por um minuto. As amostras foram então divididas em três grupos. Grupo I - controle positivo(sem preenchimento do canal radicular); Grupo II - obturação com ProRoot MTA; Grupo III -obturação com OrthoMTA III. Dez dentes foram selecionados aleatoriamente como controle negativo, no qual nenhum tratamento foi realizado. Todas as amostras foram então submetidas atestes de resistência à fratura usando uma máquina de teste universal. Para avaliação da biomineralização, seis incisivos centrais superiores foram divididos em dois grupos: grupo Iobturado com ProRoot MTA e grupo II obturado com OrthoMTA III. Essas amostras foram submetidas à análise SEM. Resultados: O grupo controle positivo demonstrou a menor resistência à fratura, enquanto o grupo OrthoMTA III apresentou a maior resistência à fratura. Não houve diferença significativa entre o grupo controle negativo e os grupos ProRoot MTA (p= 0,821). O grupo OrthoMTA III apresentou melhor biomineralização tubular quando comparado ao ProRoot MTA. Conclusões: Os canais radiculares obturados com OrthoMTA III apresentaram melhor resistência à fratura e maior biomineralização tubular em comparação como ProRoot MTA. Como os canais radiculares obturados com OrthoMTA III apresentaram melhor resistência à fratura, podendo ser utilizado como um material obturador promissor.(AU)


Subject(s)
Humans , Dental Pulp Cavity , Flexural Strength , Biomineralization
16.
RGO (Porto Alegre) ; 68: e20200001, 2020. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1091892

ABSTRACT

ABSTRACT Objective Evaluate the influence of silane heat treatment in bond durability between two resin cements and CAD/CAM feldspathic ceramic. Methods 40 feldspathic ceramic blocks were obtained, and were duplicated in microhybrid composite. All ceramic blocks were etched with 10% hydrofluoric acid for 20 s and received application of silane agent. The blocks were randomizedinto eight groups (n=5) according to the surface treatments and luting agents: P- Panavia F; PAg- Panavia F + Aging; HP- Heat Treatment + Panavia F; HPAg- Heat Treatment + Panavia F + Aging; R- RelyX ARC; Rag- RelyX ARC + Aging; HR- Heat Treatment + RelyX ARC; HRAg- Heat Treatment + RelyX ARC + Aging. The heat treatment was performed in furnace at 100 °C for 2 min. All blocks were cemented and cut to obtain samples with adhesive area of 1 mm2. Aging was performed with 10000 thermal cycles. The samples were subjected to microtensile bond strength test. Results The three-way ANOVA test revealed a significant interaction between cement versus heat treatment (p=0.001) and heat treatment versus thermal cycling (p=0.001) indicating that there was a change in bond strength due to surface treatment and aging. Conclusion Therefore, the heat treatment of the silane at 100 ºC for 2 minutes obtained higher values of bond strength between the resin cement and a feldspathic ceramicafter aging.


RESUMO Objetivo Avaliar a influência do tratamento térmico do silano na resistência de união entre dois cimentos resinosos e uma cerâmica feldspática CAD/CAM. Métodos Quarenta blocos cerâmicos foram duplicados em resina micro-híbrida. Todas as cerâmicas foram condicionadas com ácido fluorídrico 10% por 20 s e receberam aplicação do silano. Os blocos foram randomizados em oito grupos (n = 5): P-Panavia F; PAg- Panavia F + Envelhecimento; HP-Tratamento térmico + Panavia F;HPAg-Tratamento térmico + Panavia F + Envelhecimento; R-RelyX ARC; RAg-RelyX ARC; HR-Tratamento térmico + RelyX ARC; HRAg - Tratamento térmico + RelyX ARC + Envelhecimento. O tratamento térmico foi realizado em forno a 100 °C durante2 min. Todos os blocos foram cimentados e cortados para obter amostras para microtração. Foram feitos 10000 ciclos térmicos. As amostras foram submetidas a teste de micro-tração. Resultados O teste ANOVA revelou uma interação significativa entre cimento/tratamento térmico (p=0,001) e tratamento térmico/ciclo térmico (p=0,001). Conclusão Dessa maneira, o tratamentotérmico do silano a 100ºC por 2 minutos foi capaz de aumentar a resistência de união entre o cimento resinoso e uma cerâmica feldspática mesmo após o envelhecimento.

17.
J. appl. oral sci ; 28: e20200438, 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1134779

ABSTRACT

Abstract Glaze application on monolithic zirconia (Y-TZP) can be a practical approach to improve the mechanical properties of this material. Objective Our study evaluated the effect of glazing side and mechanical cycling on the biaxial flexure strength (BFS) of a Y-TZP. Methodology Eighty sintered Y-TZP discs (Ø:12 mm; thickness: 1.2 mm - ISO 6872) were produced and randomly assigned into eight groups (n=10), according to the factors "glazing side" (control - no glazing; GT - glaze on tensile side; GC - glaze on compression side; GTC - glaze on both sides) and "mechanical aging" (non-aged and aged, A - mechanical cycling: 1.2×106, 84 N, 3 Hz, under water at 37°C). Specimens were subjected to BFS test (1 mm/min; 1,000 Kgf load cell) and fractured surfaces were analyzed by stereomicroscopy and SEM. Hsueh's rigorous solutions were used to estimate the stress at failure of glazed specimens. Two-way ANOVA, Tukey's test (5%), and Weibull analysis were performed. Results The "glazing side", "mechanical aging" and the interaction of the factors were significant (p<0.05). Groups GC (1157.9±146.9 MPa), GT (1156.1±195.3 MPa), GTC (986.0±187.4 MPa) and GTC-A (1131.9±128.9 MPa) presented higher BFS than control groups (Tukey, 5%). Hsueh's rigorous solutions showed that the maximum tensile stress was presented in the bottom of zirconia layer, at the zirconia/glaze interface. Weibull characteristic strength (σo) of the GC was higher than all groups (p<0.05), except to GT, GTC-A and GTC, which were similar among them. The fractography showed initiation of failures from zirconia the tensile side regardless of the side of glaze application and fatigue. Conclusion Glazing zirconia applied on both tensile and compression sides improves the flexural strength of Y-TZP, regardless the mechanical aging.


Subject(s)
Zirconium , Dental Porcelain , Flexural Strength , Stress, Mechanical , Surface Properties , Yttrium , Materials Testing , Ceramics
18.
Braz. dent. sci ; 23(2,supl): 1-7, 2020.
Article in English | BBO, LILACS | ID: biblio-1100311

ABSTRACT

A new coronavirus disease has affected the whole world, starting from Wuhan, China at the end of 2019. The disease, caused by the pathogen of SARS-CoV-2, commonly called COVID-19, has soon passed into the history of epidemics as the most effective pandemic recently. Dentistry has also been significantly affected by the pandemic process, which had a restrictive effect on almost all aspects of social life. Dental treatments are healthcare services that have been applied very carefully in terms of the risk control of cross-infection prior to this pandemic where disinfection and sterilization rules continue to be controlled at the highest level. However, hand instruments used in most dental treatments and generating aerosol has raised concerns, particularly in diseases such as COVID-19, which increase the risk of droplet contamination. This working order is an important risk factor not only for healthcare professionals but also for the contamination of patients and the environment. In addition, the continuing pandemic process and the dynamics of the process require revision of the protocols. For this reason, each country has prepared protocols in order to maintain the dental treatments in the pandemic process in accordance with their own health care conditions and policies. This process caused the dental professionals to reconsider their routine working practices and prospectively, new protocols are recommended for dental applications. This article aims to provide a perspective evaluating the current situation and discuss additional measures to be considered during the pandemic and thereafter.(AU)


Uma nova doença por coronavírus afetou o mundo inteiro, a partir de Wuhan, China, no final de 2019. A doença, causada pelo patógeno da SARS-CoV-2, comumente chamada COVID-19, logo passou para a história das epidemias como a pandemia mais eficaz. A odontologia também foi significativamente afetada pelo processo de pandemia, que teve um efeito restritivo em quase todos os aspectos da vida social. Os tratamentos dentários são serviços de saúde que foram sempre aplicados com muito cuidado em termos de controle de risco de infecção cruzada mesmo antes desta pandemia, onde as regras de desinfecção e esterilização continuam a ser controladas ao mais alto nível. No entanto, as turbinas usadas na maioria dos tratamentos odontológicos que geram aerossóis têm suscitado preocupações, principalmente em doenças como a COVID-19, pelo aumento do risco de contaminação por gotículas. Essa mecânica de trabalho é um importante fator de risco não apenas para os profissionais de saúde, mas também para a contaminação dos pacientes e do ambiente. Além disso, o processo continuado da pandemia e sua dinâmica exigem revisão dos protocolos. Por esse motivo, cada país elaborou protocolos para manter os tratamentos dentários no processo de pandemia, de acordo com suas próprias condições e políticas de saúde. Esse processo levou os profissionais de odontologia a reconsiderar suas práticas de trabalho de rotina e, prospectivamente, novos protocolos são recomendados para aplicações odontológicas. Este artigo tem como objetivo fornecer uma perspectiva para avaliar a situação atual e discutir medidas adicionais a serem consideradas durante e após a pandemia.(AU)


Subject(s)
Infection Control , Coronavirus Infections , Coronavirus , Disease Transmission, Infectious , Betacoronavirus
19.
Braz. dent. sci ; 23(3): 1-7, 2020. ilus
Article in English | BBO, LILACS | ID: biblio-1117437

ABSTRACT

This technical report has been developed to repair the ceramic laminate veneer without removing after fracture. The bonding between the tooth and the laminate veneer is very strict, thus removing the restoration is difficult. The disadvantages such as the loss of tissue from the tooth, the cost and time loss are eliminated with this technique. In this technical report, the cementation of porcelain to porcelain in the presence of the fractured piece is explained step by step (AU)


Este relato técnico foi desenvolvido para reparar o laminado cerâmico sem remoção após fratura. A união entre o dente e o laminado é muito rígida, remover a restauração é difícil. As desvantagens como a perda de tecido do dente, o custo e a perda de tempo são eliminadas com esta técnica. Neste relato técnico, a cimentação de porcelana em porcelana na presença da peça fraturada é explicada passo a passo (AU)


Subject(s)
Cementation , Metal Ceramic Alloys , Dental Porcelain , Dental Veneers
20.
Braz. dent. j ; 30(5): 476-483, Sept.-Oct. 2019. tab, graf
Article in English | LILACS | ID: biblio-1039146

ABSTRACT

Abstract The aim of this study was to evaluate the bond strength, bottom/top hardness ratio, marginal adaptation, and interfacial nanoleakage of regular viscosity bulk fill composites (RVBFC) and regular viscosity traditional composites (RVTC). Two RVBFC (Filtek Bulk Fill and Aura Bulk Fill) and two RVTC (Filtek Z250XT and Aura) were assessed. Forty conical cavities (4.8×2.8×4.0) were prepared in bovine dentin and restored with composites (n=10). After 24h in water, marginal adaptation was evaluated by staining with a caries detector. The top and bottom surfaces of the conical restorations were stained for five seconds and the gap percentage in the composite/dentin interface was determined using digital images on a measurement program (ImageTool). The Vickers microhardness was measured and the bottom/top microhardness ratio (B/T) was determined. Push-out bond strength test was performed in a universal testing machine (0.5mm/min) and failure modes were evaluated in a stereomicroscope (20×). Other specimens (n=3) were produced for interfacial nanoleakage evaluation. Data were analyzed using one and two-way ANOVA and Tukey's test (α=0.05). The gap percentage was higher in the bottom compared to the top. The B/T ratio of the Aura Bulk Fill was statistically lower than other composites. Push-out bond strength were similar among composites. The RVBFC presented lower nanoleakage than the RVTC in the bottom of the conical restoration and there was no difference among the materials in the top surfaces. In conclusion, Filtek Bulk Fill performed better than Aura Bulk Fill regarding the analyzed properties.


Resumo O objetivo deste estudo foi avaliar a resistência de união, razão base/topo de microdureza, adaptação marginal e nanoinfiltração interfacial de resinas compostas bulk fill (BF) e tradicional (RT) de viscosidade regular.: Duas BF (Filtek Bulk Fill e Aura Bulk Fill) e duas RT (Filtek Z250XT e Aura) foram testados. Quarenta cavidades cônicas (4,8×2,8×4,0) foram preparadas em dentina bovina e restauradas com os compósitos (n=10). Depois de 24 h em água, a adaptação marginal foi avaliada por meio do corante com detector de cárie. As faces de topo e base das restaurações cônicas foram coradas por cinco segundos e a porcentagem de fendas na interface compósito/dentina foi determinada utilizando-se imagens analisadas num programa (ImageTool). A microdureza Vickers foi mensurada e a razção base/topo de microdureza (B/T) foi determinada. A resistência de união por push-out foi executada numa máquina de ensaios universal (0,5mm/min) e o padrão de fratura avaliado num estereomicroscópio (20x). Espécimes adicionais (n=3) foram confeccionados para avaliação da nanoinfiltração interfacial. Os dados foram analisados por meio de ANOVA a dois fatores e teste de Tukey (a=0,05). A porcentagem de fendas foi maior na base que no topo. A B/T da Aura Bulk Fill foi estatisticamente menor que os demais compósitos. A resistência de união por push-out foi similar entre os compósitos. As BF apresentaram menos nanoinfiltração que as RT na base das restaurações cônicas e não houve diferenças entre os materiais no topo. Conclui-se que a Filtek Bulk Fill comportou-se melhor que a Aura Bulk Fill considerando-se as propriedades analisadas.


Subject(s)
Animals , Composite Resins , Dental Caries , Viscosity , Materials Testing , Cattle , Dentin , Hardness
SELECTION OF CITATIONS
SEARCH DETAIL